技術図. Representative component image; exact configuration and appearance may vary. 画像は参考用です。納入される部品の外観は異なる場合があります。
ABB
1SBL111001R2001 — Block Contactor
電磁接触器部品番号: 1SBL111001R2001
ABB 1SBL111001R2001 (AS12-30-01-20) is a three-pole block contactor for motor and power circuit control. It has three normally open main contacts, one normally closed auxiliary contact and a 24 V AC, 50/60 Hz control coil. Its AC-3 motor rating is 5.5 kW at 400 V.
ABB 1SBL111001R2001をお探しですか。このカタログ参照品は「電磁接触器」に分類されています。部品番号と機械の情報をお送りください。仕様と供給状況を確認し、送料込みのお見積もりをご案内します。
在庫状況はお問い合わせください
技術仕様
| メーカー | ABB |
|---|---|
| 部品番号 | 1SBL111001R2001 |
| カテゴリー | 電装・制御部品 |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 72.5 mm |
| Product Net Height | 68 mm |
| Product Net Weight | 0.22 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 25 A |
| Rated Operational Current AC-1 (I e ) | 24 A at 690 V and 40 °C |
| Rated Operational Current AC-3 (I e ) | 12 A at 400 V |
| Rated Operational Current AC-15 (I e ) | (500 V) NC 2 |
| Rated Operational Current DC-13 (I e ) | (24 V) 6 A / 144 W |
| Rated Operational Power AC-3 (P e ) | 5.5 kW at 400 V |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U c ) | 24 V AC, 50 / 60 Hz |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.2 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 22 ms |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Published component type | Block Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Main Circuit Terminal Type | Screw connection |
カタログ情報には誤りや古い情報が含まれる場合があります。完全な仕様と確認済みの詳細情報はお問い合わせください。ご注文前に部品番号とお使いの機械への適合を当社にご確認ください。
製品に関するご質問
この部品に関する調査情報は、まだ日本語ではご用意できていません。担当チームにお問い合わせください。
この部品の見積もりを依頼