部品タイプの参考画像: Published product/series reference; confirm the exact configuration and supplied appearance.

部品タイプを示す参考画像であり、このブランドや部品番号そのものの写真ではありません。仕様をご確認ください。納入品の外観は異なる場合があります。

Schneider Electric

LC2D115FE7 — Reversing contactor

電磁接触器

部品番号: LC2D115FE7

LC2D115FE7 — Reversing contactor — Schneider Electric reference LC2D115FE7. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Schneider Electric LC2D115FE7をお探しですか。このカタログ参照品は「電磁接触器」に分類されています。部品番号と機械の情報をお送りください。仕様と供給状況を確認し、送料込みのお見積もりをご案内します。

在庫状況はお問い合わせください

価格はお見積もりにて

送料込み保証・サービスこの部品の見積もりを依頼

技術仕様

メーカーSchneider Electric
部品番号LC2D115FE7
カテゴリー電装・制御部品
RangeTeSys
product nameTeSys Deca
Product or Component TypeReversing contactor
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit <= 1000 V AC 25...400 Hz Power circuit <= 300 V DC
[Ie] rated operational current200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit 115 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
Motor power kW30 kW at 220...230 V AC 50-60 Hz 55 kW at 380...400 V AC 50-60 Hz 59 kW at 415 V AC 50-60 Hz 59 kW at 440 V AC 50-60 Hz 75 kW at 500 V AC 50-60 Hz 80 kW at 660...690 V AC 50-60 Hz 65 kW at 1000 V AC 50-60 Hz
motor power HP (UL / CSA)30 hp at 200/208 V AC 60 Hz for 3 phase motors 40 hp at 230/240 V AC 60 Hz for 3 phase motors 75 hp at 460/480 V AC 60 Hz for 3 phase motors 100 hp at 575/600 V AC 60 Hz for 3 phase motors
[Uc] control circuit voltage115 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current200 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1260 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current250 A 104 °F (40 °C) - 10 min for power circuit 550 A 104 °F (40 °C) - 1 min for power circuit 950 A 104 °F (40 °C) - 10 s for power circuit 1100 A 104 °F (40 °C) - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit
Average impedance0.6 mOhm - Ith 200 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 1000 V IEC 60947-4-1
Power dissipation per pole24 W AC-1 7.9 W AC-3 7.9 W AC-3e
Mounting SupportPlate Rail
Connections - terminalsControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Power circuit connector 1 0.02…0.2 in² (10…120 mm²)flexible without cable end Power circuit connector 2 0.02…0.08 in² (10…50 mm²)flexible without ca
Tightening torqueControl circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Operating time20...50 ms closing 6...20 ms opening
Maximum operating rate2400 cyc/h 140 °F (60 °C)
Control circuit voltage limits0.3...0.5 Uc (131 °F (55 °C)):drop-out AC 50/60 Hz 0.8...1.15 Uc (131 °F (55 °C)):operational AC 50/60 Hz
Inrush power in VA280…350 VA 60 Hz 0.8 68 °F (20 °C)) 280…350 VA 50 Hz 0.8 68 °F (20 °C))
Hold-in power consumption in VA2…18 VA 68 °F (20 °C)) 0.3 60 Hz 2…18 VA 68 °F (20 °C)) 0.3 50 Hz
Published component typeReversing contactor
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

カタログ情報には誤りや古い情報が含まれる場合があります。完全な仕様と確認済みの詳細情報はお問い合わせください。ご注文前に部品番号とお使いの機械への適合を当社にご確認ください。

製品に関するご質問

この部品に関する調査情報は、まだ日本語ではご用意できていません。担当チームにお問い合わせください。

この部品の見積もりを依頼

ご利用環境に合わせて設定。

言語と配送先を選択してください。最終価格と配送条件はお見積もりで確定します。