技術仕様
| メーカー | Schneider Electric |
|---|---|
| 部品番号 | LV433331 |
| カテゴリー | 電装・制御部品 |
| Range | ComPact |
| product name | ComPact NSX |
| Range of Product | ComPact NSX100...250 |
| Product or Component Type | Circuit breaker |
| Number of poles | 4P |
| Protected poles description | 3t 3t + N/2 4t |
| Line Rated Current | 40 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network Frequency | 50/60 Hz |
| [Icu] rated ultimate short-circuit breaking capacity | 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 |
| Trip unit protection functions | LSoI |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 100 kA 500 V AC 50/60 Hz IEC 60947-2 100 kA 525 V AC 50/60 Hz IEC 60947-2 100 kA 660/690 V AC 50/60 Hz IEC 60947-2 |
| Mounting Support | Backplate |
| Upside connection | Front |
| Downside connection | Front |
| Connection pitch | 1.4 in (35 mm) |
| Protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection |
| Trip unit rating | 40 A 104 °F (40 °C) |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 18...40 A |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 11 s 7.2 x Ir 16 s 6 x Ir 400 s 1.5 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Published component type | Circuit breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |