ABB

1SAM250000R1002 — Motor protection circuit-breaker

Elektrotechniek en besturing

Onderdeelnummer: 1SAM250000R1002

ABB 1SAM250000R1002 is the MS116-0.25 three-pole manual motor starter, with an adjustable overload setting of 0.16–0.25 A. It provides motor switching and protection against overload, short circuit and phase failure. The device has a rotary handle, trip class 10A and a 50 kA service short-circuit breaking capacity at 400 V AC. It is suitable for single-phase and three-phase applications, subject to correct selection and wiring.

Op zoek naar ABB 1SAM250000R1002? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.

Beschikbaarheid op aanvraag

Prijs op aanvraag

Verzending inbegrepenGarantie en serviceOfferte voor dit onderdeel aanvragen

Technische specificaties

FabrikantABB
Onderdeelnummer1SAM250000R1002
CategorieElektrotechniek en besturing
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-0.25 valid for production date from week 34/2014
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.225 kg
Rated Service Short-Circuit Breaking Capacity (I cs )50 kA at 400 V AC; 50 kA at 230 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(230 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (I i )3.1 A
Setting Range0.16–0.25 A
Rated Operational Power AC-3 (P e )0.06 kW at 400 V, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 0.06 kW
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )0.25 A
Rated Operational Current AC-3 (I e )0.25 A
Rated Operational Current AC-3e (I e )0.25 A
Rated Frequency (f)50/60 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.6 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 0.25 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Mounting35 mm DIN rail, TH35-7.5 or TH35-15

Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.