1SAM250000R1008 — Motor protection circuit-breaker
Elektrotechniek en besturingOnderdeelnummer: 1SAM250000R1008
ABB 1SAM250000R1008 is the MS116-4.0 three-pole manual motor starter and motor protection circuit-breaker. It has an adjustable 2.5–4.0 A overload setting, trip class 10A, screw terminals and a rotary ON/OFF handle. Designed for manual motor switching, it provides overload, short-circuit and phase-failure protection. Its rated service short-circuit breaking capacity is 50 kA at 400 V AC. Confirm motor and circuit requirements before selection.
Op zoek naar ABB 1SAM250000R1008? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.
Beschikbaarheid op aanvraag
Technische specificaties
| Fabrikant | ABB |
|---|---|
| Onderdeelnummer | 1SAM250000R1008 |
| Categorie | Elektrotechniek en besturing |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS116-4.0 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS116 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 85.6 mm |
| Product Net Weight | 0.265 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 230 V AC: 50 kA; 400 V AC: 50 kA; 440 V AC: 6 kA; 500 V AC: 6 kA; 690 V AC: 2 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 230 V AC: 75 kA; 400 V AC: 75 kA; 440 V AC: 18 kA; 500 V AC: 15 kA; 690 V AC: 3 kA |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 50 A |
| Setting Range | 2.5–4.0 A |
| Rated Operational Power AC-3 (P e ) | 400 V, three-phase: 1.5 kW |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 1.5 kW |
| Rated Operational Voltage | Main circuit 690 V AC |
| Rated Operational Current (I e ) | 4 A |
| Rated Operational Current AC-3 (I e ) | 4 A |
| Rated Operational Current AC-3e (I e ) | 4 A |
| Rated Frequency (f) | Main circuit 50/60 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.7 ... 1.8 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 4 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Tightening Torque | Main Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length | Main Circuit 9 mm |
| Mounting Position | 1 ... 6 |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Extended product type | MS116-4.0 |
| Trip class | 10A |
Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.