Technische illustratie — ABB 1SAM250000R1011 — 1SAM250000R1011 — Motor protection circuit-breaker

Technische illustratie. Representative component image; exact configuration and appearance may vary. Afbeeldingen zijn uitsluitend ter referentie. Het geleverde onderdeel kan er anders uitzien.

ABB

1SAM250000R1011 — Motor protection circuit-breaker

Elektrotechniek en besturing

Onderdeelnummer: 1SAM250000R1011

ABB MS116-16 (1SAM250000R1011) is a three-pole manual motor starter and motor protection circuit-breaker with an adjustable 10–16 A overload setting. It provides thermal overload and electromagnetic short-circuit protection, phase-loss sensitivity and manual switching. The device has screw terminals, a trip class of 10A and a rated operational current of 16 A.

Op zoek naar ABB 1SAM250000R1011? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.

Beschikbaarheid op aanvraag

Prijs op aanvraag

Verzending inbegrepenGarantie en serviceOfferte voor dit onderdeel aanvragen

Technische specificaties

FabrikantABB
Onderdeelnummer1SAM250000R1011
CategorieElektrotechniek en besturing
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-16
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )16 kA at 230 V AC; 16 kA at 400 V AC; 6 kA at 440 V AC; 4 kA at 500 V AC; 2 kA at 690 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )16 kA at 230 V AC; 16 kA at 400 V AC; 15 kA at 440 V AC; 10 kA at 500 V AC; 3 kA at 690 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )240 A
Setting Range10–16 A
Rated Operational Power AC-3 (P e )7.5 kW at 400 V AC, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 7.5 kW
Rated Operational Voltage690 V AC, main circuit
Rated Operational Current (I e )16 A
Rated Operational Current AC-3 (I e )16 A
Rated Operational Current AC-3e (I e )16 A
Rated Frequency (f)50/60 Hz, main circuit
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 1.1 ... 2.8 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 16 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Mounting on DIN RailTH35-7.5 or TH35-15, 35 mm DIN rail

Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.

Productvragen

Onderzoeksinformatie over dit onderdeel is nog niet beschikbaar in het Nederlands. Vraag ons team om hulp.

Offerte voor dit onderdeel aanvragen

Voel u thuis.

Kies uw taal en afleverbestemming. De definitieve prijs en verzending worden in uw offerte bevestigd.