1SAM250000R1015 — Motor protection circuit-breaker
Elektrotechniek en besturingOnderdeelnummer: 1SAM250000R1015
ABB 1SAM250000R1015 is the MS116-32 manual motor starter and motor protection circuit-breaker. It has a 25–32 A adjustable overload setting, three poles and screw terminals. It provides manual motor switching and protection against overload, short circuits and phase failure. Rated service breaking capacity is 10 kA at 400 V AC.
Op zoek naar ABB 1SAM250000R1015? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.
Beschikbaarheid op aanvraag
Technische specificaties
| Fabrikant | ABB |
|---|---|
| Onderdeelnummer | 1SAM250000R1015 |
| Categorie | Elektrotechniek en besturing |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS116-32 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS116 |
| Product Net Width | 45 mm |
| Product Net Height | 97.8 mm |
| Product Net Depth / Length | 85.4 mm |
| Product Net Weight | 0.31 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 10 kA at 230 V AC and 400 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 16 kA at 230 V AC and 400 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 480 A |
| Setting Range | 25–32 A |
| Rated Operational Power AC-3 (P e ) | 15 kW at 400 V AC, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 15 kW |
| Rated Operational Voltage | 690 V AC, main circuit |
| Rated Operational Current (I e ) | 32 A |
| Rated Operational Current AC-3 (I e ) | 32 A |
| Rated Operational Current AC-3e (I e ) | 32 A |
| Rated Frequency (f) | 50/60 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 1.9 ... 3.1 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 32 A |
| Degree of Protection | IP20 housing; IP10 main circuit terminals |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
| Tightening Torque | Main Circuit 2 N·m |
| Wire Stripping Length | Main Circuit 10 mm |
| Mounting Position | 1 ... 6 |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip class | 10A |
| DIN rail mounting | TH35-7.5 or TH35-15 |