1SAM340000R1011 — Power circuit-breaker for trafo/generator/installation protection

Elektrotechniek en besturing

Onderdeelnummer: 1SAM340000R1011

ABB MS132-16T (1SAM340000R1011) is a three-pole circuit breaker designed for primary-side protection of control transformers. It provides adjustable 10–16 A overload protection, a fixed 320 A instantaneous short-circuit setting and manual disconnection. The unit has screw terminals and a lockable rotary handle.

Op zoek naar ABB 1SAM340000R1011? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.

Beschikbaarheid op aanvraag

Prijs op aanvraag

Verzending inbegrepenGarantie en serviceOfferte voor dit onderdeel aanvragen

Technische specificaties

FabrikantABB
Onderdeelnummer1SAM340000R1011
CategorieElektrotechniek en besturing
Time-Current Characteristic CurveTripping characteristic - Circuit Breaker for Transformer Protection MS132-16T
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT
Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length86.05 mm
Product Net Weight0.310 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 230 V AC; 100 kA at 400 V AC; 30 kA at 440 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )100 kA at 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )320 A
Setting Range10–16 A
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )16 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.9 ... 2.3 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 16 A
Degree of ProtectionHousing IP20; main-circuit screw terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Tightening TorqueMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-7.5 or TH35-15, 35 mm rail, IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Published component typePower circuit-breaker for trafo/generator/installation protection
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip class10

Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.

Productvragen

Onderzoeksinformatie over dit onderdeel is nog niet beschikbaar in het Nederlands. Vraag ons team om hulp.

Offerte voor dit onderdeel aanvragen

Voel u thuis.

Kies uw taal en afleverbestemming. De definitieve prijs en verzending worden in uw offerte bevestigd.