1SAM340000R1014 — Power circuit-breaker for trafo/generator/installation protection
Elektrotechniek en besturingOnderdeelnummer: 1SAM340000R1014
ABB MS132-25T (1SAM340000R1014) is a three-pole circuit breaker designed for primary-side protection of control transformers. It provides overload and short-circuit protection, a 20–25 A adjustable overload setting, screw terminals and a lockable rotary handle with ON/OFF/TRIP indication.
Op zoek naar ABB 1SAM340000R1014? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.
Beschikbaarheid op aanvraag
Technische specificaties
| Fabrikant | ABB |
|---|---|
| Onderdeelnummer | 1SAM340000R1014 |
| Categorie | Elektrotechniek en besturing |
| Time-Current Characteristic Curve | Tripping characteristic - Circuit Breaker for Transformer Protection MS132-25T |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT |
| Product Net Width | 45 mm |
| Product Net Height | 97.8 mm |
| Product Net Depth / Length | 86.05 mm |
| Product Net Weight | 0.31 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 50 kA at 400 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 50 kA at 400 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 500 A |
| Setting Range | 20–25 A |
| Rated Operational Voltage | Main circuit: 690 V AC |
| Rated Operational Current (I e ) | 25 A |
| Rated Frequency (f) | Main circuit: 50/60 Hz |
| Operating Frequency (f sw ) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 1.2 ... 1.9 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 25 A |
| Degree of Protection | Housing: IP20; main circuit terminals: IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
| Tightening Torque | Main Circuit 2 N·m |
| Wire Stripping Length | Main Circuit 10 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 or TH35-7.5, 35 mm rail according to IEC 60715 |
| Minimum Mounting Distance | Electrical Conductive Board, Vertical 75 mm |
| Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA |
| Published component type | Power circuit-breaker for trafo/generator/installation protection |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip Class | 10 |