Technische illustratie — ABB 1SAM451000R1017 — 1SAM451000R1017 — Motor protection circuit-breaker

Technische illustratie. Representative component image; exact configuration and appearance may vary. Afbeeldingen zijn uitsluitend ter referentie. Het geleverde onderdeel kan er anders uitzien.

ABB

1SAM451000R1017 — Motor protection circuit-breaker

Elektrotechniek en besturing

Onderdeelnummer: 1SAM451000R1017

ABB 1SAM451000R1017 is the MS165-65 manual motor starter and motor protection circuit-breaker. It has a 52–65 A adjustable overload setting, three poles and screw terminals. The 400 V three-phase AC-3 rating is 30 kW. Features include trip class 10 overload protection, phase-failure sensitivity, a rotary handle and separate short-circuit trip indication.

Op zoek naar ABB 1SAM451000R1017? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.

Beschikbaarheid op aanvraag

Prijs op aanvraag

Verzending inbegrepenGarantie en serviceOfferte voor dit onderdeel aanvragen

Technische specificaties

FabrikantABB
Onderdeelnummer1SAM451000R1017
CategorieElektrotechniek en besturing
Ex Operating InstructionsATEX - Operating instructions for MS165 for potentially explosive areas
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS165-65
Cut-off Current CharacteristicCut-off Current Characteristic @ 400/690V -Manual Motor Starter MS165/MO165
Product Net Width55 mm
Product Net Height142.65 mm
Product Net Depth / Length122.1 mm
Product Net Weight0.98 kg
Rated Service Short-Circuit Breaking Capacity (I cs )(230 V AC) 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(230 V AC) 50 kA
Rated Instantaneous Short-Circuit Current Setting (I i )975 A
Setting Range52–65 A
Rated Operational Power AC-3 (P e )30 kW at 400 V, three-phase
Rated Operational Power AC-3e (P e )30 kW at 400 V, three-phase
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )65 A
Rated Operational Current AC-3 (I e )65 A
Rated Operational Current AC-3e (I e )65 A
Rated Operational Current DC-5 (I e )65 A
Rated Frequency (f)50 / 60 Hz, main circuit
Operating Frequency (f sw )0 ... 415 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 8 kV
Rated Insulation Voltage (U i )1000 V
Power Lossat Rated Operating Conditions per Pole 5.14 ... 8.02 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 65 A
Degree of ProtectionIP20 housing; IP10 main circuit terminals
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 35 mm²
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip class10

Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.

Productvragen

Onderzoeksinformatie over dit onderdeel is nog niet beschikbaar in het Nederlands. Vraag ons team om hulp.

Offerte voor dit onderdeel aanvragen

Voel u thuis.

Kies uw taal en afleverbestemming. De definitieve prijs en verzending worden in uw offerte bevestigd.