Technische illustratie — ABB 1SBH137001R1422 — 1SBH137001R1422 — Block Contactor Relay

Technische illustratie. Representative component image; exact configuration and appearance may vary. Afbeeldingen zijn uitsluitend ter referentie. Het geleverde onderdeel kan er anders uitzien.

ABB

1SBH137001R1422 — Block Contactor Relay

contactor

Onderdeelnummer: 1SBH137001R1422

ABB 1SBH137001R1422 is an NF22E-14 four-pole contactor relay for auxiliary and control circuits. It has two normally open and two normally closed mechanically linked contacts, a 250–500 V AC 50/60 Hz or DC electronic control coil, built-in surge protection and screw terminals.

Op zoek naar ABB 1SBH137001R1422? Deze catalogusreferentie is ingedeeld als ‘contactor’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.

Beschikbaarheid op aanvraag

Prijs op aanvraag

Verzending inbegrepenGarantie en serviceOfferte voor dit onderdeel aanvragen

Technische specificaties

FabrikantABB
Onderdeelnummer1SBH137001R1422
CategorieElektrotechniek en besturing
Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.31 kg
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles4P
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I th )acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (I e )6 A at 24–127 V; 4 A at 220–240 V; 3 A at 400–440 V; 2 A at 500 V; 2 A at 690 V
Rated Operational Current DC-13 (I e )6 A / 144 W at 24 V DC; 2.8 A / 134 W at 48 V DC; 1 A / 72 W at 72 V DC; 0.55 A / 60 W at 110 V DC; 0.55 A / 69 W at 125 V DC; 0.27 A / 60 W at 220 V DC; 0.27 A / 68 W at 250 V DC; 0.15 A / 60 W at 400 V DC; 0.13 A / 65 W at 500 V DC; 0.1 A / 60 W at 600 V DC
Rated Short-time Withstand Current Low Voltage (I cw )for 0.1 s 140 A
Rated Insulation Voltage (U i )acc. to IEC 60947-5-1 690 V
Rated Impulse Withstand Voltage (U imp )6 kV
Maximum Electrical Switching FrequencyAC-15: 1,200 cycles per hour; DC-13: 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (U c )250–500 V AC, 50/60 Hz; 250–500 V DC
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Mounting on DIN RailTH35-7.5 (35 × 7.5 mm) or TH35-15 (35 × 15 mm), according to IEC 60715
Mounting by Screws (not supplied)2 x M4 Screws Placed Diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Tightening TorqueAuxiliary Circuit 1.2 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay
Published component typeBlock Contactor Relay
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Surge ProtectionBuilt-in coil surge protection
Contact Configuration2 normally open and 2 normally closed mechanically linked auxiliary contacts
Ambient Operating Temperature−40 to +70 °C in free air near the contactor

Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.

Productvragen

Onderzoeksinformatie over dit onderdeel is nog niet beschikbaar in het Nederlands. Vraag ons team om hulp.

Offerte voor dit onderdeel aanvragen

Voel u thuis.

Kies uw taal en afleverbestemming. De definitieve prijs en verzending worden in uw offerte bevestigd.