Technische illustratie. Representative component image; exact configuration and appearance may vary. Afbeeldingen zijn uitsluitend ter referentie. Het geleverde onderdeel kan er anders uitzien.
1SBL357010R7211 — Block Contactor
contactorOnderdeelnummer: 1SBL357010R7211
1SBL357010R7211 — Block Contactor — ABB reference 1SBL357010R7211. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Op zoek naar ABB 1SBL357010R7211? Deze catalogusreferentie is ingedeeld als ‘contactor’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.
Beschikbaarheid op aanvraag
Technische specificaties
| Fabrikant | ABB |
|---|---|
| Onderdeelnummer | 1SBL357010R7211 |
| Categorie | Elektrotechniek en besturing |
| Product Net Width | 70 mm |
| Product Net Depth / Length | 108 mm |
| Product Net Height | 110 mm |
| Product Net Weight | 1.23 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Operational Current AC-1 (I e ) | (690 V) 40 °C 100 A |
| Rated Operational Current AC-3 (I e ) | (415 V) 55 °C 50 A |
| Rated Operational Current AC-15 (I e ) | (24 / 127 V) 6 A |
| Rated Operational Current DC-1 (I e ) | (110 V) 2 Poles in Series, 40 °C 100 A |
| Show more Rated Operational Current DC-3 (I e ) | (110 V) 2 Poles in Series, 40 °C 100 A |
| Show more Rated Operational Current DC-5 (I e ) | (110 V) 2 Poles in Series, 40 °C 80 A |
| Show more Rated Operational Current DC-13 (I e ) | (24 V) 6 A / 144 W |
| Rated Operational Power AC-3 (P e ) | (415 V) 25 kW |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 1000 V |
| Rated Impulse Withstand Voltage (U imp ) | 8 kV |
| Rated Control Circuit Voltage (U c ) | DC Operation 20 ... 60 V |
| Power Loss | at 6 A per Pole 0.1 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M6 Screws Placed Diagonally |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| Terminal Type | Ring-Tongue Terminals |
| Published component type | Block Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.