Technische illustratie — ABB 2CSA275103R1204 — 2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device

Technische illustratie. Published product/series reference; confirm the exact configuration and supplied appearance. Afbeeldingen zijn uitsluitend ter referentie. Het geleverde onderdeel kan er anders uitzien.

ABB

2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device

Elektrotechniek en besturing

Onderdeelnummer: 2CSA275103R1204

2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device — ABB reference 2CSA275103R1204. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Op zoek naar ABB 2CSA275103R1204? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.

Beschikbaarheid op aanvraag

Prijs op aanvraag

Verzending inbegrepenGarantie en serviceOfferte voor dit onderdeel aanvragen

Technische specificaties

FabrikantABB
Onderdeelnummer2CSA275103R1204
CategorieElektrotechniek en besturing
Type of Residual CurrentType A
Test Voltage (Ut)170 … 264 V
Dielectric Test Voltage2.5 kV
Rated Ultimate Short-Circuit Breaking Capacity (I cu )10 kA
Rated Residual Breaking Capacity (IΔm)6 kA
Rated Service Short-Circuit Breaking Capacity (I cs )7.5 kA
Power Supply ConnectionArbitrary
Number of Protected Poles1
Number of Poles1P+N
Operating CharacteristicInstantaneous
Position of Neutral TerminalsRight
Tightening Torque2.8 N·m
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Mounting Position of AccessoriesRight
Connecting CapacityBusbar 10 mm²
Wire Stripping Length12 mm
Terminal TypeScrew Terminals
Rated Operational Voltage230...240 V AC
Rated Insulation Voltage (U i )500 V
Rated Impulse Withstand Voltage (U imp )4 kV
Input Voltage TypeAC
Rated Current (I n )20 A
Rated Residual Current30 mA
Rated Short-Circuit Capacity10 kA
Rated Frequency (f)50 … 60 Hz
Power Loss4.2 W
Overvoltage CategoryIII
Ambient Air TemperatureOperation -25 ... 55 °C
Published component typeEarth leakage circuit breaker with auxiliary device
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.