2CSR255180R0165 — Earth leakage circuit breaker
Elektrotechniek en besturingOnderdeelnummer: 2CSR255180R0165
2CSR255180R0165 — Earth leakage circuit breaker — ABB reference 2CSR255180R0165. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Op zoek naar ABB 2CSR255180R0165? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.
Beschikbaarheid op aanvraag
Technische specificaties
| Fabrikant | ABB |
|---|---|
| Onderdeelnummer | 2CSR255180R0165 |
| Categorie | Elektrotechniek en besturing |
| Sustainable Material Content in Packaging (wt. %) | Recycled Cardboard - 98 % |
| Type of Residual Current | Type A |
| Test Voltage (Ut) | 110 ... 264 V |
| Dielectric Test Voltage | 2 kV |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 10 kA |
| Rated Residual Breaking Capacity (IΔm) | EN 61009-1 6000 A |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 7.5 kA |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (I cs ) | 6 kA |
| Power Supply Connection | Arbitrary |
| Number of Protected Poles | 1 |
| Number of Poles | 1P+N |
| Operating Characteristic | Instantaneous |
| Position of Neutral Terminals | Right |
| Tightening Torque | 2.8 N·m |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Connecting Capacity | Busbar 10 ... 10 mm² |
| Wire Stripping Length | 12 mm |
| Terminal Type | Screw Terminals |
| Rated Operational Voltage | acc. to IEC 60898-1 240 V |
| Rated Insulation Voltage (U i ) | acc. to IEC/EN 60664-1 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (I n ) | 16 A |
| Rated Residual Current | 10 mA |
| Rated Short-Circuit Capacity | 6 kA |
| Rated Conditional Short-Circuit Current (I nc ) | 10 kA |
| Rated Frequency (f) | 50 … 60 Hz |
| Power Loss | Average per Pole 2.3 W |
| Published component type | Earth leakage circuit breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.
Productvragen
Onderzoeksinformatie over dit onderdeel is nog niet beschikbaar in het Nederlands. Vraag ons team om hulp.
Offerte voor dit onderdeel aanvragen