LC1F1250 — Contactor
contactorOnderdeelnummer: LC1F1250
LC1F1250 — Contactor — Schneider Electric reference LC1F1250. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Op zoek naar Schneider Electric LC1F1250? Deze catalogusreferentie is ingedeeld als ‘contactor’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.
Beschikbaarheid op aanvraag
Technische specificaties
| Fabrikant | Schneider Electric |
|---|---|
| Onderdeelnummer | LC1F1250 |
| Categorie | Elektrotechniek en besturing |
| Range | TeSys |
| product name | TeSys F |
| Product or Component Type | Contactor |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 1260 A 104 °F (40 °C)) <= 440 V AC-1 |
| [Uc] control circuit voltage | 110...600 V AC 40...400 Hz with LX1/LX9 coil 28...250 V DC with LX4 coil |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 1260 A (at 104 °F (40 °C)) |
| Irms rated making capacity | 1890 A conforming to IEC 60947-4-1 |
| Rated breaking capacity | 1890 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 3000 A 104 °F (40 °C) - 3 min 5200 A 104 °F (40 °C) - 30 s 4000 A 104 °F (40 °C) - 1 min 2000 A 104 °F (40 °C) - 10 min 8000 A 104 °F (40 °C) - 10 s |
| Associated fuse rating | 1400 A gG at <= 440 V for power circuit |
| Average impedance | 0.12 mOhm - Ith 1260 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V IEC 60947-4-1 1500 V VDE 0110 group C |
| Power dissipation per pole | 120 W AC-1 |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.25...0.5 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.2...0.35 Uc DC with LX4 coil |
| Operating time | 40...80 ms closing with LX1/LX9 coil 100...200 ms opening with LX1/LX9 coil 60...70 ms closing with LX4 coil 40...50 ms opening with LX4 coil |
| Mounting Support | Plate |
| Connections - terminals | Power circuit bar 2 Power circuit bolted connection Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) |
| Tightening torque | Power circuit 513.3 lbf.in (58 N.m) Control circuit 10.6 lbf.in (1.2 N.m) |
| Inrush power in VA | 1500…1730 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 1420…1920 VA (at 68 °F (20 °C))with LX4 coil |
| Hold-in power consumption in VA | 20…25 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 6.5…12.5 VA (at 68 °F (20 °C))with LX4 coil |
| Maximum operating rate | 1200 cyc/h 131 °F (55 °C) |
| Published component type | Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |