Catalogusreferentie. Beschikbaarheid, exacte specificaties en originele of alternatieve levering worden in de offerte bevestigd.
XPSBAC14AP — Safety module
Elektrotechniek en besturingOnderdeelnummer: XPSBAC14AP
XPSBAC14AP — Safety module — Schneider Electric reference XPSBAC14AP. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Op zoek naar Schneider Electric XPSBAC14AP? Deze catalogusreferentie is ingedeeld als ‘Elektrotechniek en besturing’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.
Beschikbaarheid op aanvraag
Technische specificaties
| Fabrikant | Schneider Electric |
|---|---|
| Onderdeelnummer | XPSBAC14AP |
| Categorie | Elektrotechniek en besturing |
| Range of Product | Harmony Safety Automation |
| Product or Component Type | Safety module |
| Connections - terminals | Removable screw terminal block, 0.2...2.5 mm² solid or flexible Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| [Us] Rated Supply Voltage | 24 V AC - 15...10 % 24 V DC - 20...20 % |
| Synchronisation time between inputs | Unlimited |
| Power consumption in W | 1.5 W 24 V DC |
| Power consumption in VA | 3.5 VA 24 V AC 50/60 Hz |
| Input protection type | Internal, electronic |
| safety outputs | 4 NO + 1 NC |
| safety inputs | 0 |
| Input compatibility | Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 |
| input terminal | Power supply |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact 3 A AC-1 for normally closed relay contact 1 A AC-15 for normally closed relay contact 3 A DC-1 for normally closed relay contact 1 A DC-13 for normally closed relay contact |
| control outputs | 0 |
| [Ith] conventional free air thermal current | 6 A |
| Associated fuse rating | 10 A gG NO relay output circuit IEC 60947-1 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 5 V relay output |
| [Ui] rated insulation voltage | 300 V 2)IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV II IEC 60947-1 |
| Local signalling | LED green power power ON LED red error error LED yellow state status LED yellow start1 start input LED yellow start2 start input |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 4.7 in (120 mm) |
| Height | 3.9 in (100 mm) |
| Width | 0.9 in (22.5 mm) |
| Product Weight | 0.441 lb(US) (0.200 kg) |
| Published component type | Safety module |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.
Productvragen
Onderzoeksinformatie over dit onderdeel is nog niet beschikbaar in het Nederlands. Vraag ons team om hulp.
Offerte voor dit onderdeel aanvragen