Referentiebeeld van component: Published product/series reference; confirm the exact configuration and supplied appearance.

Representatief beeld van het componenttype, geen foto van dit exacte merk of onderdeelnummer. Bevestig de specificatie; het geleverde onderdeel kan er anders uitzien.

Siemens

3UG4633-2AL30 — Digital Voltage Monitoring Relay

relais

Onderdeelnummer: 3UG4633-2AL30

3UG4633-2AL30 — Digital Voltage Monitoring Relay — Siemens part reference 3UG4633-2AL30. Request a destination-specific quotation with shipping included. Confirm equipment model, serial number, quantity and any required certificates; availability, exact supply specification and warranty terms are checked before ordering.

Op zoek naar Siemens 3UG4633-2AL30? Deze catalogusreferentie is ingedeeld als ‘relais’. Stuur het onderdeelnummer en de gegevens van uw machine, zodat we de specificaties en beschikbaarheid kunnen controleren en een offerte inclusief verzending kunnen opstellen.

Beschikbaarheid op aanvraag

Prijs op aanvraag

Verzending inbegrepenGarantie en serviceOfferte voor dit onderdeel aanvragen

Technische specificaties

FabrikantSiemens
Onderdeelnummer3UG4633-2AL30
CategorieElektrotechniek en besturing
Item Type NameDigital Voltage Monitoring Relay
Product Family / SeriesSIRIUS 3UG4
Series3UG4633
Device TypeDigital monitoring relay for voltage monitoring
Connection SystemSpring-loaded (push-in) terminals
monitoring_functionOvervoltage and undervoltage (overshoot and undershoot)
voltage_typeAC/DC
control_supply_voltage17 … 275 V AC/DC
frequency50/60 Hz
power_supplySelf-supplied (internal power supply)
phases_monitored1-phase AC or DC
hysteresis_range0.1 … 150 V
tripping_delay0.1 … 20 s
starting_time1,000 ms
output_contacts1 changeover contact (SPDT / CO)
resetExternal reset and self-reset
operating_principleOpen-circuit or closed-circuit current principle
insulation_voltage_Ui690 V (overvoltage category III, pollution degree 3 per IEC 60664)
surge_immunity1 kV (IEC 61000-4-5)
ESD_immunity6 kV contact / 8 kV air discharge (IEC 61000-4-2)
RF_field_immunity10 V/m (IEC 61000-4-3)
galvanic_isolationSafe isolation between input/output, between outputs, and between supply and other circuits
mounting35 mm DIN rail
Operating Ambient Temperature-25 … +60 °C
Storage Temperature-40 … +85 °C
Transport Temperature-40 … +85 °C
Width22.5 mm
Height96 mm
Depth74 mm
Reference statusPublished catalogue reference; confirm specification and fitment before ordering
AvailabilityOn request

Catalogusinformatie kan fouten bevatten of verouderd zijn. Volledige specificaties en gecontroleerde gegevens zijn op aanvraag beschikbaar. Bevestig vóór bestelling het onderdeelnummer en de geschiktheid voor uw machine met ons.

Productvragen

Onderzoeksinformatie over dit onderdeel is nog niet beschikbaar in het Nederlands. Vraag ons team om hulp.

Offerte voor dit onderdeel aanvragen

Voel u thuis.

Kies uw taal en afleverbestemming. De definitieve prijs en verzending worden in uw offerte bevestigd.