Rysunek techniczny — ABB 1SAM250000R1014 — 1SAM250000R1014 — Motor protection circuit-breaker

Rysunek techniczny. Representative component image; exact configuration and appearance may vary. Zdjęcia mają charakter poglądowy. Wygląd dostarczonej części może się różnić.

ABB

1SAM250000R1014 — Motor protection circuit-breaker

Elektryka i sterowanie

Numer części: 1SAM250000R1014

ABB 1SAM250000R1014 is the MS116-25 manual motor starter and motor protection circuit-breaker. It provides manual switching and protection against overload, short circuit and phase failure. The three-pole unit has a 20–25 A adjustable overload range, a 25 A rated operational current and screw terminals. It is intended for single-phase or three-phase motor applications, subject to correct selection and installation.

Szukasz części ABB 1SAM250000R1014? Ta pozycja katalogowa jest sklasyfikowana jako „Elektryka i sterowanie”. Prześlij numer części i dane maszyny, abyśmy mogli sprawdzić parametry i dostępność oraz przygotować ofertę z dostawą w cenie.

Dostępność na zapytanie

Cena na zapytanie

Wysyłka w cenieGwarancja i serwisUzyskaj wycenę tej części

Specyfikacja techniczna

ProducentABB
Numer części1SAM250000R1014
KategoriaElektryka i sterowanie
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-25
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length85.4 mm
Product Net Weight0.31 kg
Rated Service Short-Circuit Breaking Capacity (I cs )10 kA at 230 V AC; 10 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(230 V AC) 16 kA
Rated Instantaneous Short-Circuit Current Setting (I i )375 A
Setting Range20–25 A
Rated Operational Power AC-3 (P e )11 kW at 400 V, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 11 kW
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )25 A
Rated Operational Current AC-3 (I e )25 A
Rated Operational Current AC-3e (I e )25 A
Rated Frequency (f)50/60 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 1.8 ... 2.8 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 25 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Tightening TorqueMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Mounting on DIN RailTH35-7.5 or TH35-15, 35 mm rail

Informacje katalogowe mogą zawierać błędy lub być nieaktualne. Pełne specyfikacje i zweryfikowane dane są dostępne na życzenie. Przed zamówieniem potwierdź z nami numer części i jej dopasowanie do maszyny.