Rysunek techniczny — ABB 1SAM340000R1003 — 1SAM340000R1003 — Power circuit-breaker for trafo/generator/installation protection

Rysunek techniczny. Representative component image; exact configuration and appearance may vary. Zdjęcia mają charakter poglądowy. Wygląd dostarczonej części może się różnić.

ABB

1SAM340000R1003 — Power circuit-breaker for trafo/generator/installation protection

Elektryka i sterowanie

Numer części: 1SAM340000R1003

ABB 1SAM340000R1003 (MS132-0.4T) is a three-pole circuit breaker designed for primary-side protection of control transformers against overload and short circuit. It has a 0.25–0.40 A adjustable current range, screw terminals and a lockable rotary handle. Its rated service breaking capacity is 100 kA at 400 V AC. Confirm suitability for the transformer and installation before selection.

Szukasz części ABB 1SAM340000R1003? Ta pozycja katalogowa jest sklasyfikowana jako „Elektryka i sterowanie”. Prześlij numer części i dane maszyny, abyśmy mogli sprawdzić parametry i dostępność oraz przygotować ofertę z dostawą w cenie.

Dostępność na zapytanie

Cena na zapytanie

Wysyłka w cenieGwarancja i serwisUzyskaj wycenę tej części

Specyfikacja techniczna

ProducentABB
Numer części1SAM340000R1003
KategoriaElektryka i sterowanie
Time-Current Characteristic CurveTripping characteristic - Circuit Breaker for Transformer Protection MS132-0.4T
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.215 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 230 V AC; 100 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(400 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (I i )8 A
Setting Range0.25 ... 0.40 A
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )0.4 A
Rated Frequency (f)Main circuit 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.6 ... 1.5 W
Number of Poles3P
Conventional Free-air Thermal Current (I th )Main Circuit 0.4 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 and TH35-7.5, 35 mm mounting rail according to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Published component typePower circuit-breaker for trafo/generator/installation protection
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10
Actuator TypeLockable rotary handle, ON / OFF / TRIP indication

Informacje katalogowe mogą zawierać błędy lub być nieaktualne. Pełne specyfikacje i zweryfikowane dane są dostępne na życzenie. Przed zamówieniem potwierdź z nami numer części i jej dopasowanie do maszyny.

Pytania o produkt

Wyniki badań dotyczących tej części nie są jeszcze dostępne po polsku. Skontaktuj się z naszym zespołem.

Uzyskaj wycenę tej części

Poczuj się jak u siebie.

Wybierz język i miejsce dostawy. Ostateczna cena i warunki wysyłki zostaną potwierdzone w wycenie.