Rysunek techniczny — ABB 1SAM340000R1006 — 1SAM340000R1006 — Power circuit-breaker for trafo/generator/installation protection

Rysunek techniczny. Representative component image; exact configuration and appearance may vary. Zdjęcia mają charakter poglądowy. Wygląd dostarczonej części może się różnić.

ABB

1SAM340000R1006 — Power circuit-breaker for trafo/generator/installation protection

Elektryka i sterowanie

Numer części: 1SAM340000R1006

ABB MS132-1.6T (1SAM340000R1006) is a three-pole circuit breaker designed for primary-side control transformer protection. It provides overload and short-circuit protection, with an adjustable 1.0–1.6 A overload setting and a fixed 32 A instantaneous short-circuit setting. The breaker has screw terminals, a rotary handle and a disconnect function.

Szukasz części ABB 1SAM340000R1006? Ta pozycja katalogowa jest sklasyfikowana jako „Elektryka i sterowanie”. Prześlij numer części i dane maszyny, abyśmy mogli sprawdzić parametry i dostępność oraz przygotować ofertę z dostawą w cenie.

Dostępność na zapytanie

Cena na zapytanie

Wysyłka w cenieGwarancja i serwisUzyskaj wycenę tej części

Specyfikacja techniczna

ProducentABB
Numer części1SAM340000R1006
KategoriaElektryka i sterowanie
Time-Current Characteristic CurveTripping characteristic - Circuit Breaker for Transformer Protection MS132-1.6T
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )100 kA at 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )32 A
Setting Range1.0–1.6 A
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )1.6 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.6 ... 1.6 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 1.6 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-7.5 or TH35-15, IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Published component typePower circuit-breaker for trafo/generator/installation protection
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10
Ambient Operating TemperatureOpen: −25 to +70 °C; temperature compensated: −25 to +60 °C

Informacje katalogowe mogą zawierać błędy lub być nieaktualne. Pełne specyfikacje i zweryfikowane dane są dostępne na życzenie. Przed zamówieniem potwierdź z nami numer części i jej dopasowanie do maszyny.