Zdjęcie poglądowe typu części: Published product/series reference; confirm the exact configuration and supplied appearance.

Poglądowe zdjęcie typu części, nie fotografia tej dokładnej marki ani numeru katalogowego. Potwierdź parametry; dostarczona część może wyglądać inaczej.

Schneider Electric

GV4AE11 — TeSys GV4 auxiliary contact block, for motor circuit breakers GV4. 1C/O contact, it performs Open/Close OF function or Trip alarm SD function, depending of its location in the…

Prowadzenie kabli i przesył energii

Numer części: GV4AE11

GV4AE11 — TeSys GV4 auxiliary contact block, for motor circuit breakers GV4. 1C/O contact, it performs Open/Close OF function or Trip alarm SD function, depending of its location in the… — Schneider Electric reference GV4AE11. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Szukasz części Schneider Electric GV4AE11? Ta pozycja katalogowa jest sklasyfikowana jako „Prowadzenie kabli i przesył energii”. Prześlij numer części i dane maszyny, abyśmy mogli sprawdzić parametry i dostępność oraz przygotować ofertę z dostawą w cenie.

Dostępność na zapytanie

Cena na zapytanie

Wysyłka w cenieGwarancja i serwisUzyskaj wycenę tej części

Specyfikacja techniczna

ProducentSchneider Electric
Numer częściGV4AE11
KategoriaProwadzenie kabli i przesył energii
RangeTeSys
Product or Component TypeAuxiliary contact
Range compatibilityTeSys TeSys GV4 TeSys TeSys BV4
[Ue] rated operational voltage<= 690 V
[Ith] conventional free air thermal current5 A IEC 60947-5-1 5 A CSA C22.2 No 14 5 A UL 508
Mounting ModeInternal mounting
[Ui] rated insulation voltage690 V IEC 60947-1
[Ie] rated operational current5 A <= 690 V AC-12 IEC 60947-5-1 5 A <= 48 V AC-15 IEC 60947-5-1 4 A 110/127 V AC-15 IEC 60947-5-1 3 A 220/240 V AC-15 IEC 60947-5-1 2.5 A 380...440 V AC-15 IEC 60947-5-1 0.11 A 660/690 V AC-15 IEC 60947-5-1 5 A <= 24 V DC-12 IEC 60947-5-1 2.5 A 48 V DC-12 IEC 60947-5-1 0.6 A 110/127 V DC-12 IEC 60947-5-1 0.3 A 250 V DC-12 IEC 60947-5-1 2.5 A <= 24 V DC-12 IEC 60947-5-1 1.2 A 48 V DC-12 IEC 60947-5-1 0.35 A 110/127 V DC-12 IEC 60947-5-1 0.05 A 250 V DC-12 IEC 60947-5-1 1 A <= 24 V DC-12 IEC 60947-5-1 0.2 A 48 V DC-12 IEC 60947-5-1 0.05 A 110/127 V DC-12 IEC 60947-5-1 0.03 A 250 V DC-12 IEC 60947-5-1
Rated power in VA120 VA AC-12 24 V IEC 60947-5-1 240 VA AC-12 48 V IEC 60947-5-1 635 VA AC-12 110/127 V IEC 60947-5-1 1200 VA AC-12 230/240 V IEC 60947-5-1 2200 VA AC-12 380/440 V IEC 60947-5-1 3450 VA AC-12 660/690 V IEC 60947-5-1
Rated power in WDC-12 120 W 24 V IEC 60947-5-1 DC-12 120 W 48 V IEC 60947-5-1 DC-12 66 W 110 V IEC 60947-5-1 DC-12 75 W 250 V IEC 60947-5-1
Associated fuse rating5 A gG at 690 V conforming to IEC 60947-5-1
Minimum switching current2 mA
Minimum switching voltage17 V
Connections - terminalsSpring terminals 1 0.0008…0.002 in² (0.5…1.5 mm²) - cable stiffness: flexible without cable end
Wire stripping length0.3 in (8 mm)
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Informacje katalogowe mogą zawierać błędy lub być nieaktualne. Pełne specyfikacje i zweryfikowane dane są dostępne na życzenie. Przed zamówieniem potwierdź z nami numer części i jej dopasowanie do maszyny.

Pytania o produkt

Wyniki badań dotyczących tej części nie są jeszcze dostępne po polsku. Skontaktuj się z naszym zespołem.

Uzyskaj wycenę tej części

Poczuj się jak u siebie.

Wybierz język i miejsce dostawy. Ostateczna cena i warunki wysyłki zostaną potwierdzone w wycenie.