Zdjęcie poglądowe typu części: Published product/series reference; confirm the exact configuration and supplied appearance.

Poglądowe zdjęcie typu części, nie fotografia tej dokładnej marki ani numeru katalogowego. Potwierdź parametry; dostarczona część może wyglądać inaczej.

Schneider Electric

GV4AU137 — TeSys GV electrical trip unit, MN undervoltage release, 110-130V AC 50/60Hz and 125V DC, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the…

Prowadzenie kabli i przesył energii

Numer części: GV4AU137

GV4AU137 — TeSys GV electrical trip unit, MN undervoltage release, 110-130V AC 50/60Hz and 125V DC, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the… — Schneider Electric reference GV4AU137. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Szukasz części Schneider Electric GV4AU137? Ta pozycja katalogowa jest sklasyfikowana jako „Prowadzenie kabli i przesył energii”. Prześlij numer części i dane maszyny, abyśmy mogli sprawdzić parametry i dostępność oraz przygotować ofertę z dostawą w cenie.

Dostępność na zapytanie

Cena na zapytanie

Wysyłka w cenieGwarancja i serwisUzyskaj wycenę tej części

Specyfikacja techniczna

ProducentSchneider Electric
Numer częściGV4AU137
KategoriaProwadzenie kabli i przesył energii
RangeTeSys
Product or Component TypeVoltage release
Range compatibilityTeSys TeSys GV4 TeSys TeSys BV4
Voltage release typeUndervoltage release
[Uc] control circuit voltage110...130 V AC 50/60 Hz 125 V DC
[Ui] rated insulation voltage130 V IEC 60947-1
Threshold tripping voltage< 0.35 Un failsafe opening 0.35...0.7 Un possible opening 0.85...1.1 Un enabled closing
Mounting ModeInternal mounting
Maximum inrush power in VA7 VA
Maximum inrush power in W2 W
Maximum hold-in power consumption in VA7 VA
Maximum hold-in power consumption in W2 W
Operating time< 50 ms
Connections - terminalsSpring terminals 1 0.0008…0.002 in² (0.5…1.5 mm²) - cable stiffness: flexible without cable end
Wire stripping length0.3 in (8 mm)
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Informacje katalogowe mogą zawierać błędy lub być nieaktualne. Pełne specyfikacje i zweryfikowane dane są dostępne na życzenie. Przed zamówieniem potwierdź z nami numer części i jej dopasowanie do maszyny.

Pytania o produkt

Wyniki badań dotyczących tej części nie są jeszcze dostępne po polsku. Skontaktuj się z naszym zespołem.

Uzyskaj wycenę tej części

Poczuj się jak u siebie.

Wybierz język i miejsce dostawy. Ostateczna cena i warunki wysyłki zostaną potwierdzone w wycenie.