Zdjęcie poglądowe typu części: Published product reference image; series and variants may differ.

Poglądowe zdjęcie typu części, nie fotografia tej dokładnej marki ani numeru katalogowego. Potwierdź parametry; dostarczona część może wyglądać inaczej.

Schneider Electric

GVAS115 — TeSys GV electrical trip, MX shunt release, 110-115V AC 50Hz / 127V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is…

Prowadzenie kabli i przesył energii

Numer części: GVAS115

GVAS115 — TeSys GV electrical trip, MX shunt release, 110-115V AC 50Hz / 127V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is… — Schneider Electric reference GVAS115. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Szukasz części Schneider Electric GVAS115? Ta pozycja katalogowa jest sklasyfikowana jako „Prowadzenie kabli i przesył energii”. Prześlij numer części i dane maszyny, abyśmy mogli sprawdzić parametry i dostępność oraz przygotować ofertę z dostawą w cenie.

Dostępność na zapytanie

Cena na zapytanie

Wysyłka w cenieGwarancja i serwisUzyskaj wycenę tej części

Specyfikacja techniczna

ProducentSchneider Electric
Numer częściGVAS115
KategoriaProwadzenie kabli i przesył energii
RangeTeSys TeSys Deca
Product or component typeShunt trip release
Range compatibilityTeSys GV2ME TeSys GV2LE TeSys GV2L TeSys GV2P TeSys GV3L TeSys GV3P TeSys Deca
[Uc] control circuit voltage127 V AC 60 Hz 110...115 V AC 50 Hz
Control circuit voltage limits0.7...1.1 Un
[Ui] rated insulation voltage690 V AC conforming to IEC 60947-1 600 V AC conforming to UL 60947-4-1 600 V AC conforming to CSA C22.2 No 60947-4-1
Threshold tripping voltage0.75...0.2 Un
Inrush power in VA14 VA AC
Inrush power in W10.5 W
Hold-in power consumption in VA5 VA AC
Hold-in power consumption in W1.6 W
Operating time10...15 ms conforming to IEC 60947-1
Connections - terminalsScrew clamp terminals 1 cable(s) 1…2.5 mm²solid Screw clamp terminals 2 cable(s) 1…2.5 mm²solid Screw clamp terminals 1 cable(s) 0.75…2.5 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.75…2.5 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.75…1.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.75…1.5 mm²flexible with cable end
Tightening torque< 1.4 N.m on screw clamp terminals
Height89 mm
Width18 mm
Depth66 mm
Product weight0.105 kg
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Informacje katalogowe mogą zawierać błędy lub być nieaktualne. Pełne specyfikacje i zweryfikowane dane są dostępne na życzenie. Przed zamówieniem potwierdź z nami numer części i jej dopasowanie do maszyny.

Pytania o produkt

Wyniki badań dotyczących tej części nie są jeszcze dostępne po polsku. Skontaktuj się z naszym zespołem.

Uzyskaj wycenę tej części

Poczuj się jak u siebie.

Wybierz język i miejsce dostawy. Ostateczna cena i warunki wysyłki zostaną potwierdzone w wycenie.